Brand Name: YORK
Model Number: YPCST18S46CAD
Place of Origin: Jiangsu, China (Mainland)
Our YORK YPC Two-Stage Absorption Chiller is the ideal choice for a wide range of industrial and commercial applications. This two-stage absorption chiller offers various burner options to meet strict emission requirements. With respect to today’s energy considerations, our two-stage absorption chiller is perfect to help you operate on a more efficient and environmentally friendly level.
We’ve designed this two-stage absorption chiller to feature versatility and reliability, excellent protection from corrosion and easy operation through intuitive controls.
Absorption chillers using lithium bromide as an absorbent have
proven to be a cost-effective and an environmentally responsible
alternative to chillers using CFC (chlorofluorocarbon) refrigerants.
However, if not properly controlled, lithium bromide is corrosive.
Therefore, steps need to be taken to protect the machine against
premature component failure that can result in increased maintenance
costs, unproductive downtime and shortened machine life. What
follows is an explanation of the need for corrosion inhibitors,
and evaluation of alternatives and a demonstration of why
ADVAGuard® 750 is the superior alternative.
Get a head start on corrosion
Corrosion brought on by lithium bromide starts very early in
the operating life of the chiller. Therefore, a corrosion inhibitor
must be present in the solution prior to commissioning
(or start-up). In the absence of an inhibitor, the corrosion
generates hydrogen gas. This gas, unless purged, will
adversely affect chiller performance.
Generally speaking, corrosion inhibitors promote the formation
of an oxide film, magnetite. It is this stable oxide layer that helps
to minimize corrosion in the machine. Fortunately, the magnetite
film forms on the steel surfaces in the vessel during initial
operation of the unit.
Maintain protection throughout machine life
To ensure the stability of this film, proper inhibitor levels must
be maintained throughout the operating life of the machine.
Unstable oxide films can lead to an increase in corrosion rates,
resulting in decreased unit life and poor system performance
from excessive hydrogen generation. An unstable film can also
result in rapid inhibitor depletion causing contamination of the
lithium bromide solution. The contaminated solution will then
need to be filtered, adding to unit maintenance costs.
All corrosion inhibitors are not equal
Customers who have experience with absorbers can relate
to the importance of a corrosion inhibitor. But far too often,
this experience leads to the misconception that all inhibitors
offer the same level of protection. Available corrosion inhibitors,
while effective in certain areas, can't offer complete protection,
for instance:
• Molybdate — currently the most commonly used inhibitor —
suffers from limited solubility in the lithium bromide solution,
making it difficult to maintain a stable concentration of
molybdate in the solution.
• Chromate inhibitors contain hazardous chromium compounds,
which are potential carcinogens.
• Nitrate inhibitors typically generate ammonia, which may
result in destructive stress cracking of the copper and copper
alloy tubes. Ammonia also acts as non-condensable gas,
which affects chiller performance.
Why ADVAGuard 750 is unsurpassed
Where other inhibitors fail, ADVAGuard 750, developed by the
lithium experts at FMC corporation, performs — time and again.
Available exclusively from Johnson Controls, it is an inorganic
corrosion inhibitor that provides superior corrosion protection.
ADVAGuard 750 is effective over a wide range of temperatures
as well, facilitating use in single-effect, double-effect and tripleeffect
machines that use lithium bromide as an absorbent.
And it’s available exclusively from Johnson Controls.
ADVAGuard 750 is a registered trademark of FMC Corporation.
ADVAGuard 750 superior advantages
• Consistently meets solubility demands — keeps chillers functioning at optimal levels
• Environmentally acceptable — it is a non-chromate inhibitor, has no hazardous by-products
• Unsurpassed film stability — holds more firmly than a magnetite layer created by a molybdate inhibitor
• Lower corrosion rate — approximately one-eighth of comparable molybdate products
• Lower rate of hydrogen generation
These advantages, along with its compatibility with most additives
used to control corrosion and heat-mass transfer properties, make it the best alternative to other available inhibitors.
ADVAGuard 750's superiority is demonstrated by unique laboratory tests developed in the research laboratories of
FMC Lithium Division. In the test, preweighed metal coupons were immersed in 65 wt% lithium bromide formulations
with the inhibitor, maintained under vacuum (29.6 inches
of Hg) at specified temperatures. Surface examination of the coupons revealed the presence of a unique protective, multilayered film of magnetite capable of withstanding
system upsets and greatly reducing corrosion rates.
Corrosion rates were calculated from weight-loss measurements.
Figures 1 and 2 illustrate the superior performance of ADVAGuard
750 corrosion inhibitor when compared to lithium molybdate.
Qinhao Zhan
HVAC&R Engineer
Refrigeration and Process Systems
China Refrigeration (York by Johnson Controls)
Mobile:+86 13818154378 18625150627
QQ: 826554493
862417098
Johnson Controls York Industrial Refrigeration - Shanghai Jiusui-Ref Systems Engineering Co., Ltd.: harsh industrial environments breakthrough in industrial refrigeration + accuracy + = large cooling load fluctuations York - Shanghai Jiusui-Ref Systems Engineering Co., Ltd tailor-made industrial refrigeration systems!
Provide personalized solutions for five major areas! Can be mainly used in petroleum, petrochemical process; chemical technology; synthetic rubber technology; fertilizer production process and chemical fiber textile technology. A number of other applications to meet different needs!
In addition to the above five major areas, York- Shanghai Jiusui-Ref Systems Engineering Co., Ltd Industrial refrigeration approved for use in air separation plants, liquefaction plants, carbon dioxide recovery systems, pharmaceutical industry, tobacco industry and steel plants, power plants, electronics factories and other process cooling And refrigeration systems.
York Shanghai Jiusui-Ref Systems Engineering Co., Ltd is located in the petrochemical industry, whether it is upstream natural gas compression, midstream liquefied natural gas storage, transshipment, or downstream air separation, liquefaction unit, as long as the compression-related York- Shanghai Jiusui-Ref Systems Engineering Co., Ltd are involved!
Advanced control system + energy efficient refrigeration equipment + overall solution = York - Shanghai Jiusui-Ref Systems Engineering Co., Ltd a full range of food refrigeration business!
Food processing + large cold storage + poultry slaughter + beer drinks + dairy products + aquatic fisheries + small logistics distribution center, etc. = York - Shanghai Jiusui-Ref Systems Engineering Co., Ltd food refrigeration business coverage!
P.K. "China cold village" -58 ℃ low temperature! (-28 ℃ ~ 15 ℃), and even tuna low-temperature cold storage (-55 ℃ ~ -60 ℃), York - Shanghai Jiusui-Ref Systems Engineering Co., Ltd food refrigeration business can be, but also the production of cold storage, Complete turnkey project. Diverse demand one stop to meet! Supporting cold storage products with cooling water system to meet the dairy products, beer and other light industry diverse needs. Sea and land to eat to ensure the quality of fish and shrimp! Provide on board and onshore fish and shrimp processing supporting the cooling and quick-frozen products, stable and reliable products to York - Shanghai Jiusui-Ref Systems Engineering Co., Ltd frozen food business filled with full.
Hot summer experience! Not only in the game-type ice rink and entertainment ice rink unique advantages, but also for the automatic ice-making plant and ice cream factory to provide frozen solution.
The trend:
increased power demand
The forecast
Energy consumption is increasing. According to the US
Energy Information Administration's (EIA) July 2013 report,
International Energy Outlook, world energy consumption
will grow by 56% between 2010 and 2040. The report
states that natural gas is the fastest growing fossil fuel,
with global consumption increasing by 1.7% yearly. Higher
demand will mean higher costs in the future.
The alternatives: add new capacity or optimize output
Gas-turbine generators are the most environmentally
clean way to generate electricity using a fossil fuel. To
meet the growing demand for power, adding additional
gas-turbine generators seems like a logical option.
However, siting new capacity is capital-intensive and can
involve long permitting periods.
A better strategy is to enhance the output of existing
generators by using Turbine Inlet Cooling (TIC) — a far
less costly alternative. The cost of implementing TIC is
$216/kW expended in one year, compared to $297/kW
expended over five years to build a new plant.
The opportunity: optimize
gas-turbine power output
The cost-effective optimized solution: inlet cooling
Today, there are various ways to enhance the power
output of gas-turbines. The most cost-effective
means is a process known as inlet cooling. This
technology can expand a gas-turbine generator’s
capacity to produce 10 to 20% more electricity at
30% less cost than producing the same amount of
power with a brand new generator.
With TIC, as the temperature of the air entering the
turbine decreases, the density of the air increases,
causing more air mass to flow through the turbine.
Greater air mass causes greater power output from
the turbine.
Mechanical cooling: the best inlet cooling method
The most consistently successful method of inlet
cooling is mechanical cooling. Based on proven waterchiller
and heat-exchanger technology, this method
provides the cooling capacity, dependability, and
constant conditions necessary to obtain optimum
output from the gas turbine. Operating the turbine
at the relatively constant conditions provided by
mechanical cooling extends the life of the turbine
and/or lowers maintenance costs.
Inside an inlet cooling solution
Model YK-EP
Centrifugal Chiller
Model CYK
Centrifugal Chiller
Model YIA
Absorption Chiller
Modular water chiller plant
Responsible for producing cooling
Centrifugal Chillers
Centrifugal chillers use mechanical cooling technology to cool
the water loop that has absorbed heat from the cooling-coil
module. As the most efficient chiller equipment, the YORK
model YK-EP chiller produces cooling at the lowest cost-perton
of refrigeration and water cooled for thermal storage at
off-peak hours. The YORK model CYK chiller provides the
most efficient operation for producing cooling, ice for thermal
storage at off-peak hours, as well as producing cooling for
high-head applications with high ambient-air temperatures.
Absorption Chillers
Absorption chillers use a chemical process to produce chilled
water. YORK model YIA and YPC absorption units use heat
sources such as gas, steam or hot water, to drive the chemical
reaction that produces economical cooling.
Filter housing with cooling-coil module
Responsible for generating the cool air stream
entering the turbine inlet
Coil
Provides the heat-transfer between
the chilled water and the incoming air,
reducing the air-inlet temperature
Filter Removes impurities from the air stream
Housing
Encloses the coil and provides
the free area to accommodate
air flow for the filter and coil
System installation strategies
A TIC system requires careful coordination in engineering and design,
equipment selection and procurement, field installation, commission,
and start-up. A typical project can take one of two approaches:
Field-erected approach: Major components are shipped to the
job site, then assembled and piped on location. This is a complex
approach involving construction managers, contractors, on-site
labor and long lead times. Completion can take up to 18 months.
Packaged approach: Equipment is integrated into a complete
system prior to shipment, then site installation is coordinated
by in-house or outside project managers. This approach is quick
and simple, taking advantage of the manufacturer’s system
and project-management expertise to provide a single-source
solution. Installation is complete within six to eight months.
System configuration
A TIC system is comprised of a number of components, including
chillers, piping, coils, controls and energy-storage tank units.
Thermal energy storage tank
Technology used to create and store thermal energy at off-peak temperature hours. Thermal
energy storage (TES) adds to the value proposition of chillers.
Thermal energy storage tanks can be
"charged" at night when electric demand is down, and "discharged" when the demand is highest.
This maximizes power production and revenue, and reduces the amount of wasted energy.
Ice Storage
Tank stores ice during low-load conditions, which can then serve as the
cooling medium at peak conditions.
Cold Water Storage Same as ice storage, but stores cold water instead of ice
Heat-rejection equipment
Equipment used to remove heat from the chillers
Water-Cooled
Cooling towers use water to remove
heat from the chiller(s)
Air-Cooled
Typically, radiators use fan-driven air to
remove heat from the chiller(s)
Make YORK®chillers your choice
for reliable inlet cooling
The OptiView control center in-use
The industrial cooling experts
When you’re selecting a chiller for a TIC system, consider
YORK chillers manufactured by Johnson Controls, the
industrial cooling experts. YORK chillers and compressors
are used in some of the most demanding, 24/7 petrochemical
and gas-compression applications on Earth. That same
industrial-grade dependability is built into all YORK chillers
that serve as the heart of a TIC system.
A TIC system can boost the turbine’s output and
reduce its capital cost, but only if the system operation
is reliable. YORK chillers are renowned for their low
incidence of repair and easy maintenance. Compressor
and control-panel design are two examples of their
industrial construction.
Open-drive compressors
Based on extensive industrial experience, YORK largetonnage
chillers use open-drive compressors, which
provide two significant uptime advantages. In the event
of an electric-motor burnout, the open motor can
be simply swapped out for repair. But with burnedout
hermetic inductor motors, the entire chiller is
contaminated with combustion products and must be
taken off-line for an extensive clean-up period. Opendrive
compressors also provide improved access for
routine maintenance tasks.
OptiView™ control center
For a clear, up-to-the-minute picture of chiller status,
YORK chillers employ the intuitive and informative
OptiView control center. The control center delivers
real-time data on all key parameters in a graphical, easyto
understand format. Powerful logging and trending
capabilities let you see how efficiently you are operating,
and provide early warning of any developing problems.
World-wide service capability
To support daily operations, Johnson Controls offers the
capabilities of the world’s largest factory-owned HVAC&R
service organization. Over 15,000 factory-trained
technicians are located in over 150 strategic locations
world-wide to handle start-up, maintenance, training,
repair, emergency, and enhancement needs. Maintenance
contracts are available to help owners quantify their
maintenance cost as a budgeted annual expense.
Energy-efficient and
environmentally responsible
by design
Environmentally acceptable refrigerants
Power plants are under close public and governmental
scrutiny for their environmental track record. By offering
chillers that have zero ozone depletion and no phaseout
date, Johnson Controls can aid in reducing your
environmental footprint. Our absorption chillers use
water as the refrigerant, while our centrifugal chillers
use refrigerant HFC-134a.
Some manufacturers use refrigerant HCFC-123. This
chemical has a phase-out schedule, meaning only a
small quantity of refrigerant will be available in the
future for servicing existing equipment; also known as
a service tail. Businesses in countries that do not have
domestic production of refrigerants will have to decide
which HCFCs to import. Since the vast majority of
installed equipment is based on HCFC-22, demand will
likely dictate the entire service tail be allocated to it.
Low parasitic energy consumption
Turbine inlet cooling provides an energy-efficient and
environmentally responsible way to enhance power
generation capacity and efficiency. This formula for
success begins with energy-efficient YORK chillers.
To minimize parasitic energy consumption, YORK chillers
are designed for real-world energy performance - the
combined performance at all operating conditions, not
just at full-load design conditions. This is critical to
maximizing energy efficiency for inlet cooling because
in the case of thermal storage application, most of the
hours are typically spent at off-design conditions. The
end result is umatched energy efficiency that saves
money and resources by returning more kW to the grid.
Model YK-EP chillers — unique
compressor arrangement reduces
energy costs in large TIC plants
If you are looking to reduce energy consumption in TIC
systems, the YORK model YK-EP chiller can help. It has a
capacity range of 2,500 to 3,200 TR (8,800 to 11,200 kW),
and features a patent-pending, mechanical-compression
economizer cycle. This economizer cycle delivers marketleading
efficiency at design conditions, particularly at
severe duty design.
In addition, at off-design conditions (with lower loads
and lower entering condenser water temperatures),
the YK-EP chiller offers energy savings that really shine.
That’s critically important in water-thermal-storage
applications, which spend the majority of their operating
hours at off-design conditions.
The YK-EP chiller can utilize entering condenser
water temperatures (ECWT) as low as 55 °F (13 °C)
to reduce instantaneous energy consumption as
much as 50% compared to chillers that can only
use 75 °F (24 °C) ECWT minimum.
A unique configuration, coupling the primary compressor with
an economizer compressor, makes the YK-EP chiller more
efficient than other chillers.
Two YK-EP chillers have an impressive 18% footprint advantage compared to the competition.
You can save energy by piping them in a seriescounterflow
arrangement, reducing the compressor work
needed on each chiller and cutting system energy use by
as much as 8% at design conditions.
Model YK chillers—superior
energy performance at
off-design conditions
Hot or cold, humid or dry – your facility must handle
the challenges of your particular climate. In fact, even
within your specific climate zone, you see variations
during days, nights, months, and seasons that create
your facility's distinct, real-world operating conditions.
These "off-design" temperatures allow YK chillers with
OptiSpeed™ variable-speed drive (VSD) to slow down
even at full loads and use 15% less electricity than
conventional fixed-speed chillers. In TIC plants that
require chillers of less than 3,000 TR (10,550 kW), the
YORK model YK chiller has a capacity range of 250–
3,000 TR (880–10,550 kW).
In the real-world, nearly 99% of a chiller’s time is spent
at off-design conditions. That’s when colder weather
conditions can reduce compressor workload by lowering
the entering condenser water temperature (ECWT). The
ability of YK chillers to take advantage of ECWT as low
as 50 °F (10 °C) reduces compressor speed at off-design
conditions. This helps deliver up to 30% more annual
energy savings than fixed-speed chillers; regardless of
how much time the chiller spends at full or part load.
Model CYK chillers — the high-head
solution for Turbine Inlet Cooling
If a TIC application entails temperatures which are
difficult for a standard centrifugal chiller to handle, the
model CYK chiller is the best answer. The CYK centrifugal
chiller incorporates a design using two centrifugal
compressors arranged in series to handle air-cooled
and brine-chilling applications at conditions outside the
range of typical centrifugal chillers.
These units use the same technology employed in
the renowned line of YORK YK single-stage centrifugal
chillers. Using HFC-134a, CYK chillers are available
in a wide range of capacities.
• For air-cooled applications (air-cooled radiators):
700 to 2,300 TR at 44 °F LWT (2,500 to 8,100 kWR
at 7 °C LWT).
•For brine chilling: 700 to 1,600 TR at 20 °F LBT
(2,500 to 5,600 kWR at -7 °C LBT)
The combination of standard components and unique
performance characteristics make CYK chillers the
technology of choice for jobs where standard chiller
designs can’t operate. Compound-system technology
provides energy and performance advantages for
TIC systems.
Understanding high-head applications
Certain job-site conditions require chillers to operate
beyond the limits found in typical air-conditioning
applications. These extreme conditions are
characterized by leaving chilled fluid temperatures
below 36 °F (2 °C), leaving condensing fluid temperatures
above 105 °F (41 °C), or a combination of both.
When the leaving chilled fluid or leaving condenser
fluid temperature exceeds standard limits, the lift on
the compressor increases dramatically. The compressor
must develop higher differential pressure on the
refrigerant gas in the compression phase, which results
in higher head pressure.
Benefits of compressor compounding
Standard components: Each CYK chiller employs common
parts instead of a one-of-a-kind design. The compressors
and heat exchangers use standard technology proven in the
successful YORK YK packaged chiller line. Each compressor
is driven by a standard, open-drive, electric motor.
Compact footprint: Compressors and motors are mounted
above the shells to assure the smallest footprint for this
type of chiller.
Greater adaptability: With the CYK chiller, the impeller
diameter, width and speed can be optimized for each
stage of compression based on operating conditions.
Operating Range
The leaving chilled and condenser
water temperatures of compound
chillers operate beyond the range
of standard chillers.
Model YIA and YPC absorption
chillers provide cooling
with minimal electricity
Absorption chillers are thermally driven: they can
utililize either natural gas, steam or hot water.
As a result they can provide TIC system cooling
while consuming very little electricity, increasing the
net electrical energy output from the power plant.
The model YPC absorption chiller represents the most
efficient, commercially available absorption technology. Its
two-stage design requires a remarkably low steam input rate
of 9.8 lbs. per ton-hour (1.26 kg per kWh), which equates to
a Coefficient of Performance (COP) of approximately 1.19.
The higher the COP, the lower the operating costs; this
means cost savings to your bottom line.
The model YIA absorption chiller can be powered by
recovered waste heat in the form of hot water or lowpressure
steam. The recovery process adds to the efficiency
of the chiller by lowering the cost of fuel, reducing overall
energy consumption, and drastically decreasing the amount
of thermal and air pollution. The YIA single-stage design can
also achieve a COP of approximately 0.70.
The YORK YIA chiller uses the best control panel
in the industry, the OptiView™ control center. It
features the revolutionary SmartPurge system, which
maintains the proper vacuum in the chiller, thereby
ensuring proper unit operation and longer life. Proper
operation is also enhanced because the control center
contains an auto-decrystallization circuit, controlled
by crystallization-prevention logic. It is designed to
keep the chiller running in even the most extreme
circumstances. Past concerns about crystallization
at low entering condensing temperatures have been
eliminated with these new controls.
YORK absorption chillers have been providing reliable
cooling for decades. The commitment Johnson Controls
has to quality, reliability and service after the sale is
evidenced by the number of YORK absorption chillers that
have been in operation for over 40 years. Johnson Controls
has a worldwide service network to provide the highest
degree of technical support regardless of your location
YORK chiller solutions meet
your specific TIC system needs
YORK chillers, manufactured by Johnson Controls,
are ideally suited for your TIC system. The broadest
array of industrial-grade chillers offer capabilities
designed to meet your exact requirements.
Energy flexibility and efficiency
YORK chillers can be driven by electricity, gas, steam,
or hot water. They offer outstanding energy efficiency
at both design and off-design conditions; for example,
YORK chillers can take advantage of colder entering
condenser water when it is available, allowing for
continued operation in fluctuating weather conditions.
Ease of operation
Microprocesser-based control centers deliver
real-time data on all key parameters in a graphical,
easy-to-understand format. This enables operators
to run the chiller more efficiently and anticipate
maintenance needs.
Customizable features
Let the industrial-cooling experience, capabilities, and
technology of Johnson Controls help your team create the
environment for success. Customize your chiller with the
following features:
• Special dimensions for overseas container shipments
or modular-package application
• Meduim-voltage motors (up to 13.8 kV)
• Special condenser waterside protection
• Special factory piping arrangement for seriescounterflow
installation
• Safety acccessories required for ice-duty operation
• Seamless integration with PLC-compatible controls
• NEMA 4X panels and wiring configuration
• Vibration monitoring
• RTD temperature sensors
• ASME documentation
• ISO quality control documentation
• AHRI factory performance testing